									SKU: ADT Series								
				Whether the function is strain gauge, ac frequency, ac voltage, ac current, slidewire etc take a look below.
Use our easy to read technical data table for configurable options for our ADT trip amplifiers.
The input(s), contacts, supply and earth are fully isolated. 
| Function | Model No. | Single Input | Dual Input | Single Trip DPCO | Dual Trip Each SPCO | Supply 24Vdc & 48Vdc - 115/230Vac | Remote set Point | Latched relay | >1% fixed deadband | Variable deadband | Upscale on open circuit | Limited Upscale drive | Downscale on open circuit | RFI Protection | LCD Display | 
 
 Bi-Colour Red/Green LED | Field Excitation | Notes | 
| Download datasheet | B | L | X | V | X | X | X | K | DI | BI | M | |||||||
| Thermocouple | ADT111 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Types: B,E,J,K,N,T,R,S. | 
| ADT112 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| Millivolt | ADT115 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | From 0-5mV to 0-400mV | 
| ADT116 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| RTD | ADT121 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | 2,3 or 4 wire connection | 
| ADT122 |   |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| RTD(Differential) | ADT125 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Both inputs 2 wire | 
| ADT126 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| Process | ADT131 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Voltage 1/P Z 1MOhm - Current 400mV drop | 
| ADT132 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| Pump Control | ADT135 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |
| Process (Diff) | ADT139 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |
| Slidewire | ADT141 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Conventional or conductive plastic 2,3 or 4 wire connection | 
| ADT142 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| Slidewire (Diff) | ADT145 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Both inputs 2 wire | 
| ADT146 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| AC Current | ADT151 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Internal VT/CT fitted for power measurement ADT151-HCT - Hall effect CT giving input range up-to 100A | 
| ADT151-HCT |  |  |  |  |  |  |  |   |   |   |   |  |  |  |  |   | ||
| AC Voltage | ADT152 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |
| AC Frequency | ADT181 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | Any regular waveform | 
| ADT182 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | ||
| Strain Gauge | ADT171 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | From 0-5mV to 0-400mV Exc 5 to 10V | 